Heat Pump Technical Info Voltage Output* Input* COP* Output, standard rating conditions** Cop, standard rating conditions** Output, low ambient** Cop, low ambient** Minimum circuit ampacity Max over current protection*** Heat exchanger Compressor Cabinet Refrigerant Refrigerant high pressure alarm Refrigerant low pressure alarm—heating units Refrigerant low pressure alarm—reverse units Low water flow alarm Maximum height below water level Minimum height above water level Optimal water flow Minimum water flow Maximum water flow Air flow Water temperature differential (Delta T) Union size Weight Sound pressure per ISO 3471 Water pressure switch Maximum height below water level EE3000T-R263 EE3000T-263 EE3000T-R EE3000T EE2500T-R263 EE2500T-263 EE2500T-R EE2500T EE2000T-263 EE2000T MODEL EE1500T EE-Ti Heat Pump Technical Specifications 230/60/1 230/60/1 230/60/3 70,000 BTUs 112,000 BTUs 3.3 kW 5.1 kW 6.4 6.4 60,000 BTUs 93,000 BTUs 5.4 5.4 40,000 BTUs 64,000 BTUs 3.7 4.0 28A 37A 27A 45A 60A 45A 40K Scroll 64 oz. R410A 2060 CFM 225 lbs. 230/60/1 230/60/3 230/60/1 230/60/3 120,000 BTUs 140,000 BTUs 5.6 kW 6.7 kW 6.3 6.1 105,000 BTUs 130,000 BTUs 5.5 5.4 72,000 BTUs 84,500 BTUs 4.0 4.0 37A 32A 37A 36A 60A 50A 60A 60A Titanium 61K Scroll 68K Scroll 83K Scroll ABS 74 oz. 90 oz. 90 oz. 90 oz. 90 oz. 114 oz. 124 oz. 114 oz. 124 oz. R410A R410A R410A R410A R410A R410A R410A R410A R410A 650 PSI (reset to 460 PSI) 58 PSI (reset to 127 PSI) 35 PSI (reset to 74 PSI) 30 GPM 10 feet below pool level 5 feet above pool level 60 GPM 30 GPM 125 GPM 4120 CFM Adjustable between 1°F to 5°F 2" 325 lbs. 58.9 dBa Adjustable between 1– 5 psi, Factory setting 2.5 psi Adjust (increase) 1 PSI for every 3 ft. below pool water level. If installed 7 ft. below pool level, replace the water pressure switch with 2-22 PSI switch R0475500 ($129.46) Chiller Specifications Output–chiller**** Input–chiller **** Cop–chiller**** Output–chiller***** Input–chiller***** Cop–chiller***** EE2500T-R 71,000 6.9 kW 3.01 87,000 7.4 kW 3.46 EE2500T-R263 71,000 6.9 kW 3.01 87,000 7.4 kW 3.46 EE3000T-R 54,000 7.2 kW 2.22 60,000 7.3 kW 2.4 EE3000T-R263 54,000 7.2 kW 2.22 60,000 7.3 kW 2.4 *Test Conditions: 80˚ F Air, 80% RH, 80˚ F Water, Outside the scope of AHRI Standard 1160 **Rated in accordance with AHRI Standard 1160 ***Max Over Current Protection refers to the maximum breaker size allowed. If this value is not a standard breaker size, use the next smallest standard size breaker. The breaker size must not be smaller than the Minimum Circuit Ampacity value. ****Test Conditions: Chiller mode, 96˚ F Air, 50% RH, 80˚ F Water, Outside the scope of AHRI Standard 1160 *****Test Conditions: Chiller mode, 96˚ F Air, 50% RH, 95˚ F Water, Outside the scope of AHRI Standard 1160 The EE series are not AHRI certified models 2015 Zodiac Pool Systems, Inc. Product Catalog 147