Close

Select Your Country

 
 
Close

Select Your Language

 
Home

ePump™ + SVRS

Energy Efficiency + Safety Vacuum Release System

ENERGY STAR certifiedIn today's world, safety and conserving energy are a must. The ePump's eight variable speeds and high efficiency motor make it the quietest and most efficient pump available, saving a tremendous amount on energy costs.

Features

  • VGB Compliant SVRS Device - Features Safety Vacuum Release System ("SVRS") technology to aid in the prevention of full body entrapment hazards in compliance with the VGB Pool & Spa Safety Act (P&SS Act). Utilizes an ANSI®/ASME® A112.19.17 certified Suction Vacuum Release System.
  • Stealth™ Pump Technology
    • Powerful, efficient operation
    • Smooth, quiet functioning with Jandy® Pro Series' Quiet Technology
    • Largest smooth surface trap basket on the market for reduced maintenance
    • Packed with user-friendly features including ergonomic handles and easy to read indicators
  • 4 Control Options - Completely programmable and customizable with 4 control system options:
    • Aqualink® RS
    • Aqualink PDA
    • Aqualink Z4
    • JEP-R Pump Controller
  • Complies with Appliance Efficiency Standards (CEC Title 20 & ANSI/APSP-15) and Qualifies for power rebates* Click here to learn more...
  • *Where offered

ModelDescription
JEP2.0SVRSePump + SVRS Variable-Speed Pump
Model HP Volts Watts Pipe Size Carton Weight Overall Length 'A'
JEP 2.0SVRS 0.25-2.7 208-230VAC 2300 W 2.5"-3" 71.5 lbs 33.5"
ModelDescription
JEP-RJandy Pro Series ePump Remote Controller
SEAQL1001Jandy Pro Series Sweep Elbow Aqualink Temp
SEFL1002Jandy Pro Series Sweep Elbow Flowlink

Air leaks are still present.

1 Check the suction side piping union. While the pump is running, try to tighten the union. If this does not stop the air leak, turn off the pump. Loosen both unions and slide the pump out of the way. Remove, clean and re-install both union o-rings.
2. Reposition the pump next to the piping and secure the union nuts to the pump. With clean union o-rings, hand tightening of the unions should create a seal. If the unions still do not seal, gently tighten with a large pair of tongue and groove pliers. DO NOT OVER-TIGHTEN.

Bubbles present in the pump basket.

1. Air in system. Check the pool or spa water level to ensure it is at the proper level and that air is not being drawn into the suction plumbing.
2. If the water is at normal level, turn off the pump. Remove the lid and check for debris around the lid o-ring seat, as this will cause air leaks in the system.
3. Clean the lid o-ring and put the lid back in place.
4. Hand tighten the lid to make an air tight seal.
5. Do not use any tools to tighten the lid. Turn the pump back on.

The cleaning/circulating system is not operating correctly.


1. Verify that the skimmer baskets, pump basket and other screens are clean. Clean as necessary.
2. Check filter and clean as necessary.
3. Check valve positions. Adjust as necessary. Note: Multiple pieces of equipment operating at one time (for example, waterfalls, spa jets, and surface returns) will affect the cleaning system and may prevent it from working properly.
4. Check the cleaning system manual to ensure that the system is adjusted according to the manufacturer's recommendations.

The pump gets hot and shuts off periodically.

1. Ensure that there is adequate room around the motor to circulate air and keep the motor cool.
2. Have a qualified electrician check for loose connections and check the voltage at the pump motor while it is in operation. The voltage must be within 10% of the motors data plate rating. If the voltage is not within 10%, contact a qualified electrician and/or the local power service provider.

The pump is leaking water between the motor and pump body.

This is caused by a damaged or failed mechanical seal. Replace the seal. See the "Mechanical Seal Replacement" portion of the manual.

There is no air in the system, but the pressure is still low.

1. It is possible that debris is caught in the impeller. The pump impeller moves the water, and the vanes in the impeller can become blocked with debris. See the "Blocked Impeller" portion of your manual for more information.

There is no debris blocking the impeller and the pressure is still low.

1. The pump impeller and diffuser are showing signs of normal wear. Have a qualified service technician check the impeller and diffuser and replace as necessary.
2. If the pump is part of a relatively new instalaltion, it could be an electrical problem. Contact a qualified service technician. Have the technician check for loose electrical connections and check the voltage at the pump motor while in operation. The voltage must be within 10% of the motor's data plate rating. If the vltage is not within 10%, contact a qualified electrician and/or the local power service provider.
3. Pump seal is leaking air. Have a qualified service technician replace the seal.

Will I lose water if I run my pool pump on Bypass?

No, you only lose water in a pool if there is a leak, through splash out, and when you backwash.

Jandy Pumps by Zodiac

ePump + SVRS Parts List

Launch our online catalog viewer to review breakout diagrams and part numbers.